Infrared CO2 Sensor Module UART/ PWM output
<
Infrared CO2 Sensor Module UART/ PWM output
Infrared CO2 Sensor Module UART/ PWM output
Infrared CO2 Sensor Module UART/ PWM output

Infrared CO2 Sensor Module UART/ PWM output

MWD1006E

Multiple output interfaces selection: UART, PWM and analog voltage output (adjustable)
Wide temperature compensation range
Anti-interference from moisture
$9.56
Quantity :
5063
-
1
+

Detail Information

Product Introduction

 

The MWD1006E is a gas detection module based on the NDIR infrared absorption technology. It uses a single light source and a single-channel detector. The sampling method use self-diffusing. MWD1006E is suitable for detecting carbon dioxide concentration in indoor and outdoor air.

 

Various output methods can be used such as digital UART, analog voltage and PWM waveform output, which is convenient for application. MWD1006E has automatic zero point calibration, sensitivity calibration and clean air calibration functions. It also provides MCDL pin for manual calibration, which is for customers to use outdoor clean air to perform relative zero point calibration on the sensor module.

 

MWD1006E can be widely used in air conditioning and fresh air control, indoor air quality monitoring, agricultural and animal husbandry production process monitoring, and can be installed in intelligent buildings, ventilation systems, controllers, wall mounted application, robots, automobiles and other applications. It can also be used for air quality monitoring in small spaces.

 

Module Characteristics 

 

● Zero point self-calibration function

● Ultra-low power consumption

● Multiple output interfaces selection: UART, PWM and analog voltage output (adjustable)

● Wide temperature compensation range

● Anti-interference from moisture

 

 

Product Specifications 

 

3.1 Working conditions 

Item Symbol Value Unit 
Storage temperatureT -20 to 80°C
Operating temperatureT -10 to + 5 0°C
Working humidityH 0 to 90% RH
Work PressureP 0.8 to 1.2atm

 

3.2 Electrical characteristics 

Item Symbol Min Typical Max Unit 
Powered byV 4.555.5V
Maximum currentI max  120150mA
Average currentI ave 303690mA

 

3.3 Technical indicators 

Item Min Typical Max Unit 
Range * 5000-ppm
Measurement accuracy±50ppm or ±5% of the true value, whichever is greaterppm
Resolution1ppm
Response time(T90)By diffusion-120-Second
Repeatability50% FS-<±5% of measured value- 
Life time3510Year

Remark: * Range can be customized

 